Influenza A Reduction

Authors
Vivienne Mahon, Science & Quality Manager
Facility
Airmid Health Group Ltd., Ireland
Download
Full Report

Objective

To evaluate the efficacy of the Defend 1050 / Pro XL on removing Influenza A.

Methodology

Testing of the Defend 1050 / Pro XL was conducted in a 28.5 m3 environmental test chamber. The chamber was preconditioned to 68±5ºF and 50±10% relative humidity prior to commencement of the tests. For the test runs, the Defend 1050 / Pro XL was placed on the floor in the center of the chamber.

Summary of Results

The Defend 1050 / Pro XL was effective in reducing airborne Influenza A aerosols in the test chamber, reaching 99.9% airborne virus reduction within the first 10 – 20 minutes of operation at max speed.

Influenza_Reduction_Graph.jpg